Product description

The Safety Gateway Starter Kit in Stainless Steel is available fully assembled and wired in a practical case.

Technical data

Type Starter Kits
Model Gateway with integrated Safety Monitor
Protection rating

IP20:
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


IP40:

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

IP54:

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


IP65:
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

IP67:

Dust-tight, full protection against contact, protection against temporary immersion.

IP20
Inputs Safety, SIL 3, Cat. 4 -
Inputs digital, EDM

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

4
Inputs safety, expandable to max. 62 x 2 channels, max. 1922 in max. configuration
Outputs Safety, SIL 3, cat. 4 4 release circuits, 2 x relay, 2 x fast electronic safe outputs
Safety outputs, independent according to SIL 3, expandable to max. 32, max. 992 in max. configuration
Safety communication Safe Link
Fieldbus interface

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU, RS 485 fieldbus

PROFIBUS
Number of AS-i networks, number of AS-i Master

Standard devices

Single Master:

1 AS-i network, 1 AS-i Master.

Double Master:

2 AS-i networks, 2 AS-i Masters.

Safety devices

Single Master:
1 AS-i network, 1 AS-i Master.

Double Master:
2 AS-i networks, 2 AS-i Masters.

Optional AS-i Safety coupling circuit:
2 AS-i networks, 1 AS-i Master.

2 AS-i networks, 2 AS-i Masters
1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

yes, max. 4 A/AS-i network:
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


no, max. 8 A/AS-i network, redundant supply:
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

no, max. 8 A/AS-i network:

1 AS-i power supply per AS-i network.

yes, max. 4 A/AS-i network
Diagnostic and configuration interface

USB:

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

Ethernet fieldbus

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

Ethernet fieldbus + Ethernet diagnostic:

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

Ethernet diagnostic:

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

Ethernet diagnostic + Modbus TCP diagnostic:

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

Ethernet fieldbus + RS 232:

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


RS 232:

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the Downloads section of the respective device.

Ethernet diagnostic
Recognition of duplicate AS-i addresses

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

yes
AS-i fault detector

Checks the AS-i line for interference effects such as noise, external voltages, ...

yes
Programming in C

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

optional