AS INTERFACE COMP. MODULE K60, DIGITAL, 4I, IP67, 4 X 1 INPUT, MAX. 200 MA, PNP, 4 X M12 STANDARD SOCKET Y-II ALLOCATION ATEX EX II 3D T60 C IP65X OBSERVE SPECIAL CONDITIONS FOR SAFE OPERATION: SUITABLE PROT. MEASURES AGAINST MECHANICAL DAMAGE REQUIRED. D

Артикул: 3RK1200-0CQ05-0AA3
Наименование: AS INTERFACE COMP. MODULE K60, DIGITAL, 4I, IP67, 4 X 1 INPUT, MAX. 200 MA, PNP, 4 X M12 STANDARD SOCKET Y-II ALLOCATION ATEX EX II 3D T60 C IP65X OBSERVE SPECIAL CONDITIONS FOR SAFE OPERATION: SUITABLE PROT. MEASURES AGAINST MECHANICAL DAMAGE REQUIRED. DETAILS SEE OPERATING INSTRUCTIONS ORDER MOUNT. PLATE 3RK19010CA00 SEPARATELY (siemens)
Производитель: Siemens


Наименование продукта
AS INTERFACE COMP. MODULE K60, DIGITAL, 4I, IP67, 4 X 1 INPUT, MAX. 200 MA, PNP, 4 X M12 STANDARD SOCKET Y-II ALLOCATION ATEX EX II 3D T60 C IP65X OBSERVE SPECIAL CONDITIONS FOR SAFE OPERATION: SUITABLE PROT. MEASURES AGAINST MECHANICAL DAMAGE REQUIRED. DETAILS SEE OPERATING INSTRUCTIONS ORDER MOUNT. PLATE 3RK19010CA00 SEPARATELY
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2001-01-01
    Версия от 2011-11-19
 
AS INTERFACE COMP. MODULE K60, DIGITAL, 4I, IP67, 4 X 1 INPUT, MAX. 200 MA, PNP, 4 X M12 STANDARD SOCKET Y-II ALLOCATION ATEX EX II 3D T60 C IP65X OBSERVE SPECIAL CONDITIONS FOR SAFE OPERATION: SUITABLE PROT. MEASURES AGAINST MECHANICAL DAMAGE REQUIRED. DETAILS SEE OPERATING INSTRUCTIONS ORDER MOUNT. PLATE 3RK19010CA00 SEPARATELY
 
General technical data:
Design of the product   digital I/O modules for operation in the field, IP67 - K60
Type   4 inputs
Design of the slave type   standard slave
I/O configuration   0
ID/ID2 code   1/F
Number / I/O sockets   4
Design of the electrical connection / of the inputs and outputs   M12 screw-type terminals
AS interface / total current input / max mA 270
operating voltage    
  • according to AS-Interface spezification
V 26.5 31.6
Ground terminal   PIN5 of each M12 socket is connected to the grounding wrist strap in the mounting plate using a pin
Addressing   front addressing socket
Application   Use in Zone 22 hazardous areas according to Classification II 3D (dusty atmosphere, non-conductive dust), resistance to shock: 1 joule Conformance with Directive 94/9/EC (ATEX) is verified through compliance with the standards EN 50281-1-1 und EN 60947-5-2
Delivery note   the modules are delivered without mounting plate
Note 1   All K60 compact modules are delivered with stainless steel screws/sockets
 
Sensor supply:
Type of voltage supply / for the sensor supply   using AS-Interface
Input voltage V 20 30
Characteristic feature of the sensor supply / short-circuit and overload resistant   Yes
Current carrying capacity / of the sensor supply / for all inputs    
  • at ambient temperature 40 °C
mA 200
 
Inputs:
Number of digital inputs   4
type of the connection technology   2 and 3-conductor technology
Input circuit   PNP transistor
Type of voltage / of the input voltage   DC
Inputs / switching level High / min V 10
Input current / at the digital input    
  • for signal <1> / minimum
mA 6
  • at signal <0> / maximum
mA 1.5
Inputs    
  • sensor supply using AS-Interface
  short-circuit and overload resistant
  • socket assignment
   
  • PIN 1
  sensor supply L+
  • PIN 2
  data input II
  • PIN 3
  sensor supply L-
  • PIN 4
  data input I
  • PIN 5
  ground terminal
Design of the pin assignment / of the inputs   Y-II assignement
 
Outputs:
Number of digital outputs   0
Outputs / external power supply 24 V DC   not required
Outputs    
  • watchdog
  not required
 
Assignment of the data bits:
Assignment of data bits    
  • socket
  PIN 4 = IN1 (D0), PIN 2 = IN2 (D1)
  • socket 2
  PIN 4 = IN2 (D1)
  • socket 3
  PIN 4 = IN3 (D2) , PIN 2 = IN4 (D3)
  • socket 4
  PIN 4 = IN4 (D3)
  • socket 5
  not assigned (closed)
  • socket 6
  not assigned (closed)
  • socket 7
  not assigned (closed)
  • socket 8
  not assigned (closed)
 
Ambient conditions:
Ambient temperature    
  • during operating
°C -25 85
  • during storage
°C -40 85
Protection class IP   IP65
 
Status display:
Status display / display of I/Os   yellow LED
Status display / display of Uaux   not required
Status display / display of AS-Interface/diagnostics   green/red LED
 
Mechanical design:
Width mm 60
Height mm 152
Depth mm 29
Type of mounting   standard rail mounting/wall mounting using mounting plate for K60 compact module
 
Certificates/approvals:
AS-Interface certificate   yes (or requested for in case of new units)
Approvals   UL, CSA, shipbuilding (or requested for in case of new units)
Explosion protection category for dust   (Ex) II 3D Ex tD A22 IP65X T60°C
Limiting conditions for safe operation   Suitable measures must be taken to protect the module from mechanical damage. All M12 connectors must be secured by a lock-clip against unauthorized opening such that the connector cannot be disconnected by hand but only by destroying the lock-clip. A suitable lock-clip is available from Binder GmbH + Co., Elektrische Bauelemente KG, Postfach 1152, 74148 Neckarsulm, Germany, Tel. +49 (0)7132/325-0, Fax +49 (0)7132/325-150, info@binder-connector.de, Article No. 16-0977-000. All the M12 sockets which are not assigned must be closed with 3RK1 901-1KA01 caps (tamper-proof version) such that they cannot be released by hand. Addressing the module using the 3RK1 904-2AB01 addressing unit is only permitted outside the EX-Zone 22. When the addressing operation is finished, the addressing socket must be closed with a 3RK1 901-1KA01 sealing cap (tamper-proof version) such that it cannot be released by hand. If an additional supply (AUX POWER) is required, it must comply with VDE 0106 (PELV), protection class III.
Safety and commissioning instructions   The devices are approved for an ambient temperature of -25 to +85 °C. The devices must be configured, connected and commissioned by qualified, responsible personnel only. An incorrect response may cause serious injury to persons and damage to property. It is assumed that personnel are familiar with the assignment of classes to the permitted hazardous zones. The plug connectors and AS-Interface cables must not be connected or disconnected when live. The units require no maintenance. No modifications or repairs are allowed to be carried out on the units. All the above points must be observed in the event of replacement. See also Regulations for Installation EN 60079-14 / EN 50281-1-2.
General Product Approval
 
 
 
last change:
Oct 31, 2011