SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/5,5KW; 1,5A...12,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q

Артикул: 3RK1315-6LS41-1AA0
Наименование: SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/5,5KW; 1,5A...12,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0 (siemens)
Производитель: Siemens


Наименование продукта
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/5,5KW; 1,5A...12,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2009-05-15
    Версия от 2012-03-11
 
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/5,5KW; 1,5A...12,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
 
General technical data:
product brand name   SIRIUS
product designation   motor starter M200D, AS-i Basic
Design of the product   reversing starter
Product function    
  • direct start
  No
  • reverse starting
  Yes
  • short circuit protection
  Yes
  • bus-communication
  Yes
Design of the switching contact   electromechanical
Product component / outlet for enine brake   No
Trip class   CLASS 10
Type of assignement   1
Product equipment    
  • brake control with 230 V AC
  No
  • brake control with 400 V AC
  No
  • brake control with 24 V DC
  No
  • brake control with 180 V DC
  No
  • brake control with 500 V DC
  No
Product extension / braking module for brake control   No
Impulse voltage resistance / rated value V 6,000
Start-up delay time ms 85
Switch-off delay time ms 65
Insulation voltage / rated value V 500
Active power loss / typical W 30
Maximum permissible voltage for safe disconnection    
  • between main circuit and auxiliary circuit
V 400
  • between control and auxiliary circuit
V 24
Item designation    
  • according to DIN EN 61346-2
  Q
Type of mounting   screw fixing
Width mm 294
Height mm 215
Depth mm 159
 
Main circuit:
Operating voltage    
  • rated value
V 360 440
Adjustable response current    
  • of the current-dependent overload release
A 1.5 12
Operating current / at AC-3 / at 400 V    
  • rated value
A 12
Service power / for three-phase servomotors / at 400 V / at 50 Hz    
  • for AC three-phase
kW 0.55 5.5
Service power / at AC-3    
  • at 400 V / rated value
kW 5.5
  • at 500 V / rated value
W 5,500
Number of poles / for main current circuit   3
Design of the short-circuit protection   circuit-breakers
Breaking capacity limit short-circuit current (lcu)    
  • at 400 V / rated value
A 50,000
  • at 500 V / rated value
A 50,000
Type of the motor protection   full motor protection
 
Control circuit:
Type of voltage / of the controlled supply voltage   DC
Control supply voltage / 1 / for DC / rated value V 24
Control supply voltage / 1 / for DC / rated value / permissible minimum V 20.4
Control supply voltage / 1 / for DC / rated value / permissible maximum V 28.8
Design of the electrical connection / for auxiliary and control current circuit   connector
 
Supply voltage:
Type of voltage / of supply voltage   DC
Supply voltage / 1 / for DC / rated value V 30
  • permissible minimum
V 26.5
  • permissible maximum
V 31.6
Design of the electrical connection / for supply voltage infeed   M12 plug
 
Ambient conditions:
Protection class IP   IP65
Ambient temperature    
  • during storage
°C -40 +70
  • during operating
°C -25 +55
  • during transport
°C -40 +70
Relative humidity    
  • during operating phase
% 10 95
Resistance against vibration   7 mm / 2g
Resistance against shock   12g / 11 ms
Degree of pollution   3
Installation altitude / at a height over sea level / maximum m 2,000
Built in orientation   vertical, horizontal, flat
Built in orientation / recommended   horizontal
 
Communication:
Design of the interface    
  • AS interface protocol
  Yes
Protocol / will be supported    
  • AS interface protocol
  Yes
Design of the interface    
  • PROFIBUS DP protocol
  No
Protocol / will be supported    
  • PROFIBUS DP protocol
  No
Product function    
  • control circuit interface with IO link
  No
  • control circuit interface to parallel wiring
  No
Design of the interface    
  • PROFINET protocol
  No
Protocol / will be supported    
  • PROFINET protocol
  No
Design of the electrical connection    