| SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER STANDARD ELECTRONICALLY SWITCHING 3 400V AC/5.5KW; 1.5A...12.00A; ELECTRONIC OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 400V AC 4DI / 1DO AS-I HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH |
|
General technical data: |
product brand name | | SIRIUS |
product designation | | motor starter M200D, AS-i Standard |
Design of the product | | reversing starter |
Product function | | |
| | No |
| | Yes |
| | Yes |
| | Yes |
Design of the switching contact | | solid-state / thyristor / 2 phases |
Product component / outlet for enine brake | | Yes |
Trip class | | CLASS 5, 10, 15, 20 |
Type of assignement | | 1 |
Product equipment | | |
- brake control with 230 V AC
| | Yes |
- brake control with 400 V AC
| | Yes |
- brake control with 24 V DC
| | No |
- brake control with 180 V DC
| | No |
- brake control with 500 V DC
| | No |
Product extension / braking module for brake control | | No |
Impulse voltage resistance / rated value | V | 6,000 |
Start-up delay time | ms | 25 |
Switch-off delay time | ms | 35 |
Insulation voltage / rated value | V | 500 |
Active power loss / typical | W | 30 |
Maximum permissible voltage for safe disconnection | | |
- between main circuit and auxiliary circuit
| V | 400 |
- between control and auxiliary circuit
| V | 24 |
Item designation | | |
- according to DIN EN 61346-2
| | Q |
Type of mounting | | screw fixing |
Width | mm | 294 |
Height | mm | 215 |
Depth | mm | 159 |
|
Main circuit: |
Operating voltage | | |
| V | 360… 440 |
Adjustable response current | | |
- of the current-dependent overload release
| A | 1.5… 12 |
Operating current / at AC-3 / at 400 V | | |
| A | 12 |
Service power / for three-phase servomotors / at 400 V / at 50 Hz | | |
| kW | 0.55… 5.5 |
Service power / at AC-3 | | |
| kW | 5.5 |
| W | 5,500 |
Number of poles / for main current circuit | | 3 |
Design of the short-circuit protection | | circuit-breakers |
Breaking capacity limit short-circuit current (lcu) | | |
| A | 50,000 |
| A | 20,000 |
Type of the motor protection | | full motor protection |
|
Control circuit: |
Type of voltage / of the controlled supply voltage | | DC |
Control supply voltage / 1 / for DC / rated value | V | 24 |
Control supply voltage / 1 / for DC / rated value / permissible minimum | V | 20.4 |
Control supply voltage / 1 / for DC / rated value / permissible maximum | V | 28.8 |
Design of the electrical connection / for auxiliary and control current circuit | | connector |
|
Supply voltage: |
Type of voltage / of supply voltage | | DC |
Supply voltage / 1 / for DC / rated value | V | 30 |
| V | 26.5 |
| V | 31.6 |
Design of the electrical connection / for supply voltage infeed | | M12 plug |
|
Ambient conditions: |
Protection class IP | | IP65 |
Ambient temperature | | |
| °C | -40… +70 |
| °C | -25… +55 |
| °C | -40… +70 |
Relative humidity | | |
| % | 10… 95 |
Resistance against vibration | | 7 mm / 2g |
Resistance against shock | | 12g / 11 ms |
Degree of pollution | | 3 |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Built in orientation | | vertical, horizontal, flat |
Built in orientation / recommended | | horizontal |
|
Communication: |
Design of the interface | | |
| | Yes |
Protocol / will be supported | | |
| | Yes |
Design of the interface | | |
| | No |
Protocol / will be supported | | |
| | No |
Product function | | |
- control circuit interface with IO link
| | No |
- control circuit interface to parallel wiring
| | No |
Design of the interface | | |
| | No |
Protocol / will be supported | | |
| | No |
Design of the electrical connection | | |
|