| SIRIUS SOFT STARTER, SIZE S3, 106A, 55KW/400V, 40 DEGREES, 200-480V AC, 110-230V AC/DC, SCREW TERMINALS |
|
General details: |
product brand name | | SIRIUS |
Product equipment | | |
- integrated bridging contact system
| | Yes |
| | Yes |
Product function | | |
- intrinsic device protection
| | No |
- motor overload protection
| | No |
- evaluation of thermal resistor motor protection
| | No |
| | No |
- adjustable current limitation
| | No |
| | No |
Product component / outlet for enine brake | | No |
Item designation | | |
- according to DIN EN 61346-2
| | Q |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | G |
|
Power Electronics: |
product designation | | soft starters for standard applications |
Operating current | | |
| A | 106 |
| A | 98 |
| A | 90 |
Emitted mechanical power / for three-phase servomotors | | |
- at 230 V / at standard switching / at 40 °C
| | |
| W | 30,000 |
- at 400 V / at standard switching / at 40 °C
| | |
| W | 55,000 |
yielded mechanical performance (hp) / for three-phase squirrel cage motors / at 200/208 V / at standard circuit / at 50 °C / rated v
alue | hp | 30 |
Operating frequency | | |
| Hz | 50… 60 |
Relative negative tolerance / of the operating frequency | % | -10 |
Relative positive tolerance / of the operating frequency | % | 10 |
Operating voltage / with standard circuit / rated value | V | 200… 480 |
Relative negative tolerance / of the operating voltage / with standard circuit | % | -15 |
Relative positive tolerance / of the operating voltage / with standard circuit | % | 10 |
Minimum load in % of l_M | % | 10 |
Continuous operating current in % of l_e / at 40°C | % | 115 |
Active power loss / at operating current / at 40°C / during operating phase / typical | W | 21 |
|
Control electronics: |
Type of voltage / of the controlled supply voltage | | AC/DC |
Control supply voltage frequency / 1 / rated value | Hz | 50 |
Control supply voltage frequency / 2 / rated value | Hz | 60 |
Relative negative tolerance / of the control supply voltage frequency | % | -10 |
Relative positive tolerance / of the control supply voltage frequency | % | 10 |
Control supply voltage / 1 / at 50 Hz / for AC | V | 110… 230 |
Control supply voltage / 1 / at 60 Hz / for AC | V | 110… 230 |
Relative negative tolerance / of the control supply voltage / at 60 Hz / for AC | % | -15 |
Relative positive tolerance / of the control supply voltage / at 60 Hz / for AC | % | 10 |
Control supply voltage / 1 / for DC | V | 110… 230 |
Relative negative tolerance / of the control supply voltage / for DC | % | -15 |
Relative positive tolerance / of the control supply voltage / for DC | % | 10 |
Type of display / for fault signal | | red |
|
Mechanical design: |
Size of the engine control device | | S3 |
Width | mm | 70 |
Height | mm | 170 |
Depth | mm | 190 |
Type of mounting | | screw and snap-on mounting |
Built in orientation | | With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back |
Distance, to be maintained, to the ranks assembly | | |
| mm | 60 |
| mm | 30 |
| mm | 40 |
Altitude of installation site / at a height over sea level | m | 5,000 |
Cable length / maximum | m | 300 |
Number of poles / for main current circuit | | 3 |
|
Electrical connections: |
Design of the electrical connection | | |
| | screw-type terminals |
- for auxiliary and control current circuit
| | screw-type terminals |
Number of NC contacts / for auxiliary contacts | | 0 |
Number of NO contacts / for auxiliary contacts | | 1 |
Number of change-over switches / for auxiliary contacts | | 0 |
Type of the connectable conductor cross-section / for main contacts / for box terminal / when using the front clamping point | | |
| | 2x (2.5 ... 16 mm²) |
- finely stranded / with conductor end processing
| | 2.5 ... 35 mm² |
| | 4 ... 70 mm² |
Type of the connectable conductor cross-section / for main contacts / for box terminal / when using the back clamping point | | |