| CURRENT MEASURING MODULE; SET CURRENT 2,4...25A; OVERALL WIDTH 45MM; STRAIGHT-THROUGH CT |
|
General technical data: |
product brand name | | SIRIUS |
product designation | | current measuring module |
Protection class IP | | IP20 |
Built in orientation | | any |
EMC immunity to interference / according to IEC 60947-1 | | corresponds to degree of severity 3 |
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV |
Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 | | 2 kV |
Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 | | 1 kV |
Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m |
EMC emitted interference / according to IEC 60947-1 | | class A |
Resistance against vibration | | 1-6 Hz / 15 mm; 6-500 Hz / 2 g |
Impulse voltage resistance / rated value | V | 6,000 |
Insulation voltage / rated value | V | 690 |
Number of outputs / as contact-affected switching element | | 0 |
Adjustable response current | | |
- of the current-dependent overload release
| | |
| A | 2.4 |
| A | 25 |
Product component | | |
- input for thermistor connection
| | No |
Product function | | |
| | No |
| | Yes |
Item designation | | |
- according to DIN EN 61346-2
| | F |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | F |
|
Communication: |
Product function | | |
| | No |
|
Main circuit: |
Number of poles / for main current circuit | | 3 |
Operating frequency | | |
| Hz | 50… 60 |
Operating voltage | | |
- at 50 Hz / at AC / rated value
| V | 110… 690 |
- at 60 Hz / at AC / rated value
| V | 110… 690 |
|
|
Control circuit: |
Type of voltage | | |
- of the controlled supply voltage
| | AC |
|
Installation/mounting/dimensions: |
Type of mounting | | screw and snap-on mounting |
Width | mm | 45 |
Height | mm | 84 |
Depth | mm | 45 |
|
Connections: |
Product function | | |
- removable terminal for auxiliary and control circuit
| | No |
Design of the electrical connection | | |
| | straight-through transformers |
|
Ambient conditions: |
Installation altitude / at a height over sea level / maximum | m | 4,000 |
Ambient temperature | | |
| °C | -40… +80 |
| °C | -25… +60 |
| °C | -40… +80 |
Relative humidity / during operating phase | % | 5… 95 |
|
Certificates/approvals: |
Verification of suitability | | CE / UL / CSA / CCC / C-TICK / GOST / NOM / ATEX / NEPSI / ABS / DNV / GL / LRS / RoHS |
|
Certificates/approvals: | | |
General Product Approval | For use in hazardous locations | | |
| |
|
last change: | Feb 6, 2012 |