FAIL-SAFE DIGITAL MODULE DM-F PROFISAFE; FOR FAIL-SAFE SWITCH-OFF VIA BUS / PROFISAFE; UV: 24 V DC, 2 RELAY ENABLING CIRCUITS; 2 RELAY OUTPUTS; 3 OUTPUTS; MAX. ERR. SIL (IEC 61508): 3; MAX. ERR. PL (ISO 13849-1): E;

Артикул: 3UF7330-1AB00-0
Наименование: FAIL-SAFE DIGITAL MODULE DM-F PROFISAFE; FOR FAIL-SAFE SWITCH-OFF VIA BUS / PROFISAFE; UV: 24 V DC, 2 RELAY ENABLING CIRCUITS; 2 RELAY OUTPUTS; 3 OUTPUTS; MAX. ERR. SIL (IEC 61508): 3; MAX. ERR. PL (ISO 13849-1): E; (siemens)
Производитель: Siemens


Наименование продукта
FAIL-SAFE DIGITAL MODULE DM-F PROFISAFE; FOR FAIL-SAFE SWITCH-OFF VIA BUS / PROFISAFE; UV: 24 V DC, 2 RELAY ENABLING CIRCUITS; 2 RELAY OUTPUTS; 3 OUTPUTS; MAX. ERR. SIL (IEC 61508): 3; MAX. ERR. PL (ISO 13849-1): E;
Жизненный цикл продукта
3UF7330-1AB00-0">
3UF7330-1AB00-0"> Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
3UF7330-1AB00-0"> 2011-06-01
FAIL-SAFE DIGITAL MODULE DM-F PROFISAFE; FOR FAIL-SAFE SWITCH-OFF VIA BUS / PROFISAFE; UV: 24 V DC, 2 RELAY ENABLING CIRCUITS; 2 RELAY OUTPUTS; 3 OUTPUTS; MAX. ERR. SIL (IEC 61508): 3; MAX. ERR. PL (ISO 13849-1): E;
 
General technical data:
product brand name   SIRIUS
Item designation / according to DIN EN 61346-2   F
Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750   F
 
Installation/mounting/dimensions:
Built in orientation   any
Type of mounting   screw and snap-on mounting
Width mm 45
Height mm 106
Depth mm 124
 
Connections:
Design of the electrical connection / for auxiliary and control current circuit   screw-type terminals
Conductor cross-section that can be connected / for auxiliary contact    
  • solid
mm² 0.5 4
  • stranded wire
   
  • with conductor end processing
mm² 0.5 2.5
 
Ambient conditions:
Ambient temperature    
  • during operating
°C -25 +60
  • during storage
°C -40 +80
  • during transport
°C -40 +80
Relative humidity    
  • during operating phase
% 5 95
Installation altitude / at a height over sea level / maximum m 2,000
Protection class IP   IP20
Resistance against vibration   1-6 Hz / 15 mm; 6-500 Hz / 2 g
EMC immunity to interference / according to IEC 60947-1   corresponds to degree of severity 3
Conductor-bound parasitic coupling BURST    
  • according to IEC 61000-4-4
  2 kV network connection / 1 kV control connection
Conductor-bound parasitic coupling conductor-earth SURGE    
  • according to IEC 61000-4-5
  1 kV
Conductor-bound parasitic coupling conductor-conductor SURGE    
  • according to IEC 61000-4-5
  0.5 kV
Field-bound parasitic coupling    
  • according to IEC 61000-4-3
  10 V/m
EMC emitted interference / according to IEC 60947-1   class A
Insulation voltage / rated value V 300
Impulse voltage resistance / rated value V 4,000
 
Safety:
safety Integrated Level / according to IEC 61508   SIL3
Performance level (PL) / according to ISO 13849-1   e
Category / according to EN 954-1   4
Category / according to ISO 13849-1   4
Product function    
  • emergency stop function
  No
  • automatic start
  No
  • monitored start-up
  No
  • light barrier monitoring
  No
  • protective door monitoring
  No
  • magnetic switch monitoring Normally closed contact-Normally open contact
  No
  • light grid monitoring
  No
  • magnetic switch monitoring Normally closed contact-Normally closed contact
  No
  • step mat monitoring
  No
Acceptability for application    
  • EMERGENCY-OFF circuit monitoring
  No
  • safety-related circuits
  No
  • position switch monitoring
  No
  • safety cut-out switch
  No
  • magnetically operated switches monitoring
  No
  • proximity switches monitoring
  No
  • tactile sensor monitoring
  No
  • opto-electronical protection device monitoring
  No
  • valve monitoring
  No
Product feature / transverse contact-secure   Yes
Design of the input / reducing-entrance   Yes
Probability of dangerous failure per hour (PFHD) / with high demand rate / according to EN 62061 1/h 0.43599999999999994E-8
Average probability of failure on demand (PFDavg) / with low demand rate / according to IEC 61508 1/y 0.513E-5
SIL claim limit (for a subsystem) / according to EN 62061   3
T1 value / for proof test interval or service life / according to IEC 61508 a 20
PROFIsafe monitoring time F_WD_Time ms 250
Response time / in faultless state WCDT ms 150
Response time / in case of failure OFDT ms 200
Backslide delay time / at mains power cut / typical ms 40
Backslide delay time / at mains power cut / maximum ms 80
Recovery time / after mains power cut / typical s 1
 
Communication:
Protocol / will be supported / PROFIsafe protocol   Yes
 
Inputs/ Outputs:
Number of inputs   4
Number of digital inputs   3
Number of analog inputs   0
Number of outputs   2
Number of outputs / as contact-affected switching element   2
Switching behaviour   monostable
Number of analog outputs   Назад в раздел