Product type designation | SCALANCE XR324-4M EEC |
| SCALANCE XR324-4M EEC; MANAGED IE SWITCH, 19" RACK, POWER SUPPLY WITH 1 X 230V AC DATA CABLE OUTLET FRONT SIDE, 16 X 10/100/1000MBIT/S RJ45 PORTS ELECTRICAL, 4 X 100/1000MBIT/S FOR 2-PORT- MEDIA MODULES, ELECTRICAL OR OPTICAL, LED DIAGNOSTICS, FAULT SIGNAL CONTACT WITH SELECT/SET-BUTTON, PROFINET-IO DEVICE, NETWORK- MANAGEMENT, INTEGRATED REDUNDANCY MANAGER |
Transmission rate | |
Transfer rate / 1 | 10 Mbit/s |
Transfer rate / 2 | 100 Mbit/s |
Transfer rate / 3 | 1000 Mbit/s |
Interfaces | |
Number of electrical/optical connections / for network components or terminal equipment / maximum | 24 |
Number of electrical connections | |
- for network components and terminal equipment
| 16 |
| 1 |
| 1 |
| 4 |
| 1 |
- for redundant power supply
| 0 |
Design of electrical connection | |
- for network components and terminal equipment
| RJ45 port |
| RJ11 port |
| 3-pole terminal block |
| 3-pole terminal block |
Design of optical interface / for optical waveguide | |
| Dependent on selected media modules |
| Dependent on selected media modules |
design of the removable storage / C-PLUG | Yes |
Inputs/outputs | |
Operating voltage / of signaling contacts / at AC / rated value | 276 V |
Operating current / of signaling contacts / at AC / maximum | 5 A |
Operating voltage / of signaling contacts / at DC / rated value | 230 V |
Operating current / of signaling contacts / at DC / maximum | 0.1 A |
Supply voltage, current consumption, power loss | |
Type of supply voltage / redundant power supply unit | No |
Type of voltage / of supply voltage | AC |
Supply voltage | |
| 230 V |
| 80 V… 276 V |
Type of voltage / 2 / of the supply voltage | DC |
Supply voltage / for DC | 220 V |
| 48 V… 300 V |
Product component / fusing at power supply input | Yes |
Type of fusing / at input for supply voltage | 3.15A / 250V |
Consumed current / maximum | 0.7 A |
Active power loss | |
| 42 W |
| 42 W |
Permitted ambient conditions | |
Ambient temperature | |
| -40 °C… 70 °C |
| -40 °C… 70 °C |
| -40 °C… 70 °C |
| Extended temperature upper limit of +85° C permitted for 16 hours. Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C) |
Relative humidity / at 25 °C / without condensation / during operating / maximum | 95 % |
Protection class IP | IP20 |
Design, dimensions and weight | |
Design | 19" rack |
Width | 483 mm |
Height | 44 mm |
Depth | 305 mm |
Net weight | 6.6 kg |
Type of mounting | |
| Yes |
| No |
| No |
| No |
Type of mounting | When used in shipbuilding, the device must be secured in the 19" rack at four points |
Product properties, functions, components / general | |
Cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s | 50 |
Cascading in cases of star structuring | Any (depending only on signal propagation time) |
Product function | |
| Yes |
| Yes |
| Yes |
| Yes |
- Configuration with STEP 7
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Protocol / is supported | |
| Yes |
| Yes |
| Yes |
| Yes |
| Назад в раздел
|