AS-Interface sensor/actuator module | VAA-4EA-G4-ZE/E2

Артикул: VAA-4EA-G4-ZE/E2
Наименование: AS-Interface sensor/actuator module | VAA-4EA-G4-ZE/E2
Производитель: Pepperl-Fuchs


Not available for purchase, If you need assistance please contact us sales@quad-industry.com
Оборудование снято с производства, для уточнения замены свяжитесь с нами sales@quad-industry.com

  • AS-Interface certificate
  • Protection degree IP65
  • Flat or round cable connection (via standardized EEMS base, not included with delivery)
  • Cable piercing method for flat cable
  • Communication monitoring, turn-off
  • Inputs for 2- and 3-wire sensors
  • Power supply of outputs from the external auxiliary voltage
  • Power supply of inputs from the module
  • Function display for bus, ext. auxiliary voltage, inputs and outputs
  • Monitoring of sensor overloads

Datasheet as PDF in following languages:


Technical Data: VAA-4EA-G4-ZE/E2

Product Description
G4 module IP65
4 inputs (PNP) and 4 electronic outputs
General specifications
Slave typeStandard slave
AS-Interface specificationV2.0
Required master specification≥ V2.0
UL File NumberE87056
Indicators/operating means
LED PWR/FAULTdual LED green/red
green: AS-Interface voltage
red: overload sensor supply
LED INswitching state (input); 4 LED yellow
LED OUTSwitching state (output); 4 LED yellow
LED AEext. auxiliary voltage UAUX ; LED green
Electrical specifications
Auxiliary voltage (output)24 V DC ± 15 % PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 60 mA (without sensors) / max. 240 mA
Protection classIII
Input
Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface
Voltage21 ... 31 V
Current loading capacity≤ 180 mA (TB ≤ 40 В°C),
≤ 140 mA (TB ≤ 60 В°C), short-circuit protected
Input current≤ 8 mA (limited internally)
Switching point
0 (unattenuated)≤ 1.5 mA
1 (attenuated)≥ 4.5 mA
Output
Number/Type4 electronic outputs, PNP
Supplyfrom external auxiliary voltage UAUX
Current2 A per output, 4 A total
Voltage≥ (UAUX - 0.5 V)
Programming instructions
ProfileS-7.F
IO code7
ID codeF
Data bits (function via AS-Interface) input output
D0 IN1 OUT1
D1 IN2 OUT2
D2 IN3 OUT3
D3 IN4 OUT4
Parameter bits (programmable via AS-i)function
P0communication monitoring
P0 = 1 (basic setting), monitoring = ON, i.e. if communication fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1not used
P2not used
P3not used
Compliance with standards and directives
Standard conformity
Protection degreeEN 60529
Ambient conditions
Ambient temperature-25 ... 60 В°C (-13 ... 140 В°F)
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Mechanical specifications
Protection degreeIP65
Connectioncable piercing method or terminal compartment
yellow flat cable/black flat cable or standard round cable
inputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals
Mass350 g
MountingDIN rail or screw mounting