  • Sensing range up to 15 m
  • Resolution 30 mm (hand protection)
  • Protective field height up to 1800 mm
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Master/Slave detection, Plug and Play
  • Start/Restart disable
  • Protection degree IP67
  • Integrated function display
  • Pre-fault indication
  • Safety outputs OSSD in potential-separated semiconductor design or with monitored, compelled connection NC-contacts
  • Optional with relay monitor (Option 129)
  • Optional with ATEX certificates for zone 2 and 22 and protection degree IP66 (Option 133)

Datasheet as PDF in following languages:


Technical Data: SLC30-1200

General specifications
Effective detection range0.2 ... 15 m
Light sourceIRED
Light typemodulated infrared light
Safety type according to IEC/EN 614964
MarkingCE
Protection field height1200 mm
Number of beams64
Operating modecan be selected with or without start/restart disable
Optical resolution30 mm
Angle of divergence< 5 В°
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd1.35 E-8
Indicators/operating means
Diagnostics display7-segment display in receiver
Function displayin receiver:
LED red: OSSD off
LED green: OSSD on
LED yellow: Protected area free, system start-ready
Pre-fault indicationLED orange
Electrical specifications
Operating voltage24 V DC (-30 %/+25 %)
Input
Function inputStart release
Output
Safety output2 separated fail safe semiconductor outputs
Signal output1 PNP each, max. 100 mA for start readiness and OSSD status
Mechanical specifications
Protection degreeIP67
ConnectionM20 cable gland ,
terminal compartment with screw terminals, lead cross-section max. 1.5 mm2